点击听全文,今天大家继续一起学IEC61400-1。

3.41 rated power 额定功率

quantity of power assigned, generally by a manufacturer, for a specified operating condition of a component, device or equipment.

一般由设备制造商给定,部件、装置或设备在规定运行工况下对应的功率标称值。

Note 1 to entry: For a wind turbine, it is the maximum continuous electrical power output which a wind turbine is designed to achieve under normal operating and external conditions.

注释 1:对于风力发电机组,额定功率指机组在正常运行及外部环境条件下,设计可稳定输出的最大电功率。

3.42 rated wind speed 额定风速 \(V_r\)

minimum wind speed at hub height at which a wind turbine's rated power is achieved in the case of steady wind without turbulence.

无湍流稳态风况下,轮毂高度处风机刚好输出额定功率的最低风速。

3.43 Rayleigh distribution 瑞利分布 \(P_R\)

probability distribution function.

一种概率分布函数。

Note 1 to entry: See 3.68.

注释 1:参见 3.68 条款。

3.44 reference wind speed 参考风速 \(V_{ref}\)

basic parameter for wind speed used for defining wind turbine classes.

用于划定风机等级的基础风速参数。

Note 1 to entry: Other design related climatic parameters are derived from the reference wind speed and other basic wind turbine class parameters (see Clause 6).

注释 1:其余设计相关气候参数均由参考风速与其他风机等级基础参数推导得到(见第 6 章)。

Note 2 to entry: A turbine designed for a wind turbine class with a reference wind speed Vref is designed to withstand climates for which the extreme 10 min average wind speed with a return period of 50 years at turbine hub height is lower than or equal to Vref.

注释 2:以参考风速Vref型设计的风机,可适配轮毂高度处 50 年重现期 10 分钟平均极端风速不大于Vref的气候环境。

3.45 resistance partial safety factor 抗力分项安全系数 \(\gamma_M\)

factor which takes account of possible unfavourable deviations/uncertainties of the material strength parameters and of the resistance model including bias in the resistance model.

该系数用于考量材料强度参数、抗力计算模型存在的不利偏差与不确定性,同时包含抗力模型自带的系统偏差。

3.46 rotationally sampled wind velocity 旋转采样风速

原文:wind velocity experienced at a fixed point of the rotating wind turbine rotor.

旋转的风机风轮上某一固定质点所感受到的风速。

Note 1 to entry: The turbulence spectrum of a rotationally sampled wind velocity is distinctly different from the normal turbulence spectrum. While rotating, the blade cuts through a wind flow that varies in space. Therefore, the resulting turbulence spectrum will contain sizeable amounts of variance at the frequency of rotation and harmonics of the same.

注释 1:旋转采样风速的湍流谱与常规湍流谱存在明显区别;叶片旋转过程中扫掠空间分布不均的流场,最终形成的湍流谱会在风轮旋转频率及其倍频处产生较大的方差分量。

3.47 rotor speed 风轮转速

rotational speed of a wind turbine rotor about its axis.

风机风轮绕自身旋转主轴的转动速度。

3.48 roughness length 地表粗糙度长度 \(z_0\)

extrapolated height at which the mean wind speed becomes zero if the vertical wind profile is assumed to have a logarithmic variation with height.

假定风速沿高度呈对数廓线分布时,将风速廓线外推至平均风速为零对应的虚拟高度。

3.49 safe-life 安全寿命

design property for a critical system which is either very difficult to repair or may cause severe damage to life and property.

针对检修难度大、失效后易造成重大人身与财产损失的关键系统所设定的设计属性。

Note 1 to entry: Such systems are designed to work for the full system lifetime without requirement of any repairs or inspections.

注释 1:此类系统的设计要求为:在整机全寿命周期内无需开展任何维修与检查作业。

3.50 safety integrity level 安全完整性等级(SIL)

discrete level (one out of a possible four), corresponding to a range of safety integrity values for the control functions, where 4 and 1 belong to the highest and lowest levels, respectively.

分为四档的离散等级,对应控制功能不同区间的安全完整性数值,其中 SIL4 为最高等级,SIL1 为最低等级。

Note 1 to entry: Target failure measures for the four safety integrity levels are defined in Tables 2 and 3 of IEC 61508-1:2010. These levels can be used for specifying safety integrity requirements of safety functions allocated to the systems. A SIL is not a property of a system, subsystem, element or component. As defined in IEC 61508-1, the phrase "SIL n safety-related system" (where n is 1, 2, 3, or 4) means that the system is potentially capable of supporting safety functions with a safety integrity level up to n.

注释 1:IEC 61508-1:2010 表 2、表 3 规定了四类安全完整性等级对应的目标失效指标;该等级用于规定分配至系统的安全功能的完整性要求。SIL 并非系统、子系统、元器件本身的固有属性;依据 IEC 61508-1 定义,“SIL n 级安全相关系统”(n 取 1、2、3、4)代表该系统最高可承载对应 n 等级的安全功能。

3.51 scheduled maintenance 定期维护

preventive maintenance carried out in accordance with an established schedule.

按照既定计划表执行的预防性维护作业。

3.52 secondary layer protection function 次级保护功能

dedicated protection function which operates using a layer of monitoring and logic separate from a primary layer protection function (3.39) with a similar purpose.

拥有独立监测与逻辑回路的专用保护功能,和 3.39 条款的主层级保护功能防护目标一致,二者相互独立冗余。

3.53 site data 场址数据

environmental, seismic, soil and electrical network data for the wind turbine site.

风机场址对应的环境、地震、岩土以及电网相关实测资料。

Note 1 to entry: Wind data shall be the statistics of 10 min samples unless otherwise stated.

注释 1:若无特殊说明,风况数据均采用 10 分钟采样的统计值。

3.54 standstill 静止停机状态

condition of a wind turbine that is stopped.

风机风轮完全停止转动的运行状态。

3.55 support structure 支撑结构

part of a wind turbine comprising the tower and foundation.

由塔筒与基础共同构成的风机支承体系。

3.56 survival wind speed 生存风速

maximum wind speed that a construction is designed to withstand.

结构设计所能承受的最大风速。

Note 1 to entry: This is a popular expression that is not used in this document. Design conditions instead refer to extreme wind speed (3.19).

注释 1:该词汇仅为行业俗称,本标准不予采用,设计工况统一使用 3.19 条款定义的极端风速。

3.57 swept area 扫掠面积

原文:projected area perpendicular to the wind direction that a rotor will describe during one complete rotation翻译:风轮旋转一周,叶片在垂直于来流风向平面上扫掠形成的投影总面积。

3.58 turbulence intensity 湍流强度 I

ratio of the wind speed standard deviation to the mean wind speed, determined from the same set of measured data samples of wind speed, and taken over a specified period of time.

同一组风速实测样本、规定时长内,风速标准差与平均风速的比值。

3.59 turbulence scale parameter 湍流尺度参数

wavelength where the non-dimensional, longitudinal power spectral density is equal to 0,05.

无量纲纵向功率谱密度等于 0.05 时所对应的波长数值。

Note 1 to entry: The wavelength is thus defined as 

注释 1:因此该波长定义为:

  简单总结  

该部分为 IEC 61400-1:2019 第 3 章术语,规范了风机额定参数、风场基础参数、结构抗力系数、旋转流场特性、安全寿命与 SIL 安全等级、主次两级保护机制、场址勘测数据、湍流特征参数等专业定义,为风机载荷计算、安全系统设计、风资源实测分析提供统一的术语基准。

来源:智慧强学斋
ACTSystem湍流UG岩土UM电机Electric材料控制
著作权归作者所有,欢迎分享,未经许可,不得转载
首次发布时间:2026-07-30
最近编辑:26天前
强学斋
硕士 签名征集中
获赞 19粉丝 66文章 161课程 0
点赞
收藏
作者推荐

大家一起学标准之IEC61400-1(2)

今天继续学习IEC61400-1. INTRODUCTIONThis part of IEC 61400 outlines minimum design requirements for wind turbines and is not intended for use as a complete design specification or instruction manual.Any of the requirements of this document may be altered if it can be suitably demonstrated that the safety of the system is not compromised. This provision, however, does not apply to the classification and the associated definitions of external conditions in Clause 6. Compliance with this document does not relieve any person, organization, or corporation from the responsibility of observing other applicable regulations.This document is not intended to give requirements for wind turbines installed offshore, in particular for the support structure. For offshore installations, reference is made to the IEC 61400-3 series.引言本部分 IEC 61400 标准规定风电机组最低限度设计要求,不作为完整的产品设计规范或使用操作手册。若能够充分论证修改条款后不会损害整机系统安全性,则本文件内任意条款均可进行调整;但第 6 章中外部环境分级及其配套定义不得修改。即便产品符合本文件各项要求,相关个人、机构、企业仍需遵守其他适用法律法规,不得因此豁免法定合规义务。本文件不适用于海上风电机组(尤其是支撑结构部分);海上风机设计应参照 IEC 61400-3 系列标准。WIND ENERGY GENERATION SYSTEMS –Part 1: Design requirements1 ScopeThis part of IEC 61400 specifies essential design requirements to ensure the structural integrity of wind turbines. Its purpose is to provide an appropriate level of protection against damage from all hazards during the planned lifetime.This document is concerned with all subsystems of wind turbines such as control and protection functions, internal electrical systems, mechanical systems and support structures.This document applies to wind turbines of all sizes. For small wind turbines, IEC 61400-2 can be applied. IEC 61400-3-1 provides additional requirements to offshore wind turbine installations.This document is intended to be used together with the appropriate IEC and ISO standards mentioned in Clause 2.风能发电系统第 1 部分:设计要求1 范围本部分 IEC 61400 标准规定核心设计要求,保障风电机组结构完整性,旨在使机组在设计寿命周期内,针对各类风险具备合理的防护能力,避免发生损毁。本文件覆盖风电机组全部子系统,包括控制与保护功能、机组内部电气系统、机械系统以及支撑结构。本标准适用于全规格尺寸的风电机组;小型风电机组可执行 IEC 61400-2;IEC 61400-3-1 针对海上风电机组项目补充专项设计要求。本文件需与第 2 章所列对应的 IEC、ISO 配套标准配合使用。2 Normative referencesThe following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.IEC 60034 (all parts), Rotating electrical machinesIEC 60038, IEC standard voltagesIEC 60071-1, Insulation co-ordination – Part 1: Definitions, principles and rulesIEC 60071-2, Insulation co-ordination – Part 2: Application guidelinesIEC 60076 (all parts), Power transformersIEC 60204-1, Safety of machinery – Electrical equipment of machines – Part 1: General requirementsIEC 60204-11:2000, Safety of machinery – Electrical equipment of machines – Part 11: Requirements for HV equipment for voltages above 1 000 V AC or 1 500 V DC and not exceeding 36 kVIEC 60364 (all parts), Low voltage electrical installationsIEC 60529, Degrees of protection provided by enclosures (IP Code)IEC 60664-1, Insulation coordination for equipment within low-voltage systems – Part 1: Principles, requirements and testsIEC 60664-3, Insulation coordination for equipment within low-voltage systems – Part 3: Use of coating, potting or moulding for protection against pollutionIEC 60721 (all parts), Classification of environmental conditionsIEC 61000-6-2, Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity standard for industrial environmentsIEC 61400-3, Wind turbines – Part 3: Design requirements for offshore wind turbinesIEC 61400-4, Wind Turbines – Part 4: Design requirements for wind turbine gearboxesIEC 61400-24, Wind turbines – Part 24: Lightning protectionIEC 61439 (all parts), Low-voltage switchgear and controlgear assembliesIEC 61800-4, Adjustable speed electrical power drive systems – Part 4: General requirements – Rating specifications for AC power drive systems above 1 000 V AC and not exceeding 35 kVIEC 61800-5-1, Adjustable speed electrical power drive systems – Part 5-1: Safety requirements – Electrical, thermal and energyIEC 62271 (all parts), High-voltage switchgear and controlgearIEC 62305-3, Protection against lightning – Part 3: Physical damage to structures and life hazardIEC 62305-4, Protection against lightning – Part 4: Electrical and electronic systems within structuresIEC 62477-1:2012, Safety requirements for power electronic converter systems and equipment – Part 1: GeneralISO 76, Rolling bearings – Static load ratingsISO 281, Rolling bearings – Dynamic load ratings and rating lifeISO 2394, General principles on reliability for structuresISO 2533, Standard AtmosphereISO 4354, Wind actions on structuresISO 6336-2, Calculation of load capacity of spur and helical gears – Part 2: Calculation of surface durability (pitting)ISO 6336-3:2006, Calculation of load capacity of spur and helical gears – Part 3: Calculation of tooth bending strengthISO 12494:2001, Atmospheric icing on structuresISO 13850, Safety of machinery – Emergency stop function – Principles for designISO/TS 162881, Rolling bearings – Methods for calculating the modified reference rating life for universally loaded bearings2 规范性引用文件下列文件在本标准中被引用,其全部或部分条文构成本标准的强制性要求。注日期引用文件仅采用标注版本;未注日期引用文件采用其最新有效版本(含所有修改单)。IEC 系列引用标准1.IEC 60034(所有部分):旋转电机2.IEC 60038:IEC 标准电压3.IEC 60071-1:绝缘配合 第 1 部分:定义、原则与规则4.IEC 60071-2:绝缘配合 第 2 部分:应用导则5.IEC 60076(所有部分):电力变压器6.IEC 60204-1:机械安全 机械电气设备 第 1 部分:通用要求7.IEC 60204-11:2000:机械安全 机械电气设备 第 11 部分:交流 1000V / 直流 1500V~36kV 高压设备要求8.IEC 60364(所有部分):低压电气装置9.IEC 60529:外壳防护等级(IP 代码)10.IEC 60664-1:低压系统内设备绝缘配合 第 1 部分:原则、要求与试验11.IEC 60664-3:低压系统内设备绝缘配合 第 3 部分:采用涂覆、灌封、模塑方式实现防污秽防护12.IEC 60721(所有部分):环境条件分类13.IEC 61000-6-2:电磁兼容 (EMC) 第 6-2 部分:通用标准 工业环境抗扰度标准14.IEC 61400-3:风电机组 第 3 部分:海上风电机组设计要求15.IEC 61400-4:风电机组 第 4 部分:风电机组齿轮箱设计要求16.IEC 61400-24:风电机组 第 24 部分:雷电防护17.IEC 61439(所有部分):低压成套开关设备和控制设备18.IEC 61800-4:可调速电力传动系统 第 4 部分:通用要求 交流 1000V~35kV 传动系统额定规范19.IEC 61800-5-1:可调速电力传动系统 第 5-1 部分:安全要求 电气、热、能量相关安全20.IEC 62271(所有部分):高压开关设备和控制设备21.IEC 62305-3:雷电防护 第 3 部分:建筑物物理损伤与人身危险防护22.IEC 62305-4:雷电防护 第 4 部分:建筑物内电气与电子系统防护23.IEC 62477-1:2012:电力电子变流系统与设备安全要求 第 1 部分:总则ISO 系列引用标准1.ISO 76:滚动轴承 额定静载荷2.ISO 281:滚动轴承 额定动载荷与额定寿命3.ISO 2394:结构可靠性通用原则4.ISO 2533:标准大气条件5.ISO 4354:结构上的风荷载作用6.ISO 6336-2:圆柱齿轮与锥齿轮承载能力计算 第 2 部分:齿面接触疲劳(点蚀)校核7.ISO 6336-3:2006:圆柱齿轮与锥齿轮承载能力计算 第 3 部分:轮齿弯曲强度校核8.ISO 12494:2001:结构大气覆冰9.ISO 13850:机械安全 急停功能 设计原则10.ISO/TS 162881:滚动轴承 全工况载荷下修正参考额定寿命计算方法今天这段规范是IEC 61400-1:2019《风力发电机组 第 1 部分:设计要求》的引言和前两章。引言说明本标准仅规定陆上风机最低设计底线,除第6章外部环境分类不可改动外,其余条款可在论证安全不受影响后调整,海上风机需遵循IEC 61400-3系列。第1章界定标准适用全尺寸陆上风机,覆盖整机所有子系统以保障全生命周期结构安全;第2章罗列了本标准编制与执行必须配套采用的IEC、ISO各类电气、机械、防雷、载荷相关规范性引用文件。今天就学到这里,明天我们继续学习,每天十分钟大家一起学标准。来源:智慧强学斋

未登录
还没有评论
课程
培训
服务
行家
VIP会员 学习计划 福利任务
下载APP
联系我们
帮助与反馈